STAB KNIFE 45 DEGREE

$46.00

SKU: 1727450 Categories: , ,

MAKEDGE

Ophthalmic Micro Surgical Knives

Consistent Performance :

MAKEDGE ophthalmic surgical instruments are engineered for consistent performance, enhancing reliability and safety across surgical procedures. Manufactured with an advanced automated process known as electro-etching, each blade is precisely formed for high sharpness and uniform quality. Every instrument is produced through controlled processes that uphold strict quality standards, delivering dependable performance for healthcare professionals and safe use in surgical environments.

Precise and Sharper Blade :

MAKEDGE instruments are crafted using advanced electro-etching and electro-polishing processes to produce sharp, high-precision blades. This manufacturing approach supports reliable blade quality that aligns with the demands of modern ophthalmic surgery. The precision blades help surgeons perform fine ophthalmic procedures with control and accuracy, contributing to consistency in surgical performance.

Anti-Glare :

MAKEDGE instruments feature a matte finish designed to reduce glare from operating room lighting. This helps improve visibility of the blade within the eye chamber and supports a clearer view of the surgical field, aiding focus during intricate ophthalmic procedures.

IFU FOR OPHTHALMIC KNIVES

Intended use

Ophthalmic Microsurgical Knives are used to make precise incisions for ophthalmic surgery the precise incisions achievable with these knives are among the preconditions for application in delicate ophthalmic surgical interventions.

Further information

1.    Construction

 

a. Handling of the case

I) Taking out the knife: Take special care to prevent the blade from coming into contact with any part of the packaging. Gently pick up the device and lift the knife from the locking position.

II) Replacing the knife: Hold the knife with the blade edge facing downward. Align it properly with the locking position in the tray. Press down gently until the handle clicks into place, ensuring the knife is securely locked.

 

  1. Material

Blade: Stainless steel
Handle: Polycarbonate
Tray: Polycarbonate

  1. Each ophthalmic knife is individually packed and sealed in a pouch to ensure sterility. These products are sold in boxes.
  2. The device is intended to be used by a trained ophthalmic surgeon

Instruction for use

Select the appropriate type of knife for each surgical purpose. Use in accordance with the usual surgical procedures.

Warnings/Precautions for safe handling

  • Read, follow, and retain the Instructions for Use.
  • Use the product only for its intended purpose. Refer to the Intended Use section.
  • Store products in a dry, clean and secure environment.
  • Avoid exposure to high temperatures, high humidity, direct sunlight, or moisture. Store at room temperature.
  • Do not store near chemicals or in areas where gas emissions may occur.
  • Preserve the product under conditions where the packaging remains undamaged and free from any breaks or pinholes. Do not use if the packaging is broken or contains pinholes.
  • Always check the expiration date on each package and box.
  • Dispose of any product that has exceeded its expiration date.
  • Prior to each use, inspect the product for signs of damage, such as looseness, bending, breakage, cracking, wear, or fracture.
  • Do not use the product if it is damaged or defective. Set it aside and do not attempt to repair or reuse it.
  • Ensure the blade does not come into contact with any surface or object before use.
  • Dispose of the used knife with medical waste disposal protocols.
  • Use the knife immediately after unpacking. Dispose of the used knife carefully to prevent infection.

Contraindication-Prohibition

Contraindication-Prohibition

  • Do Not Reuse

This device is supplied sterile and intended for single use only. It must be disposed of after use in accordance with hospital policy. Reusing the device may lead to serious infections and other complications.

  • Do Not Re-sterilize

If the sterile barrier is compromised, the device is no longer sterile and must not be re-sterilized. Using such a device may result in infection or other adverse outcomes for the patient.

  • Do Not Use After Expiry Date

Always verify the expiration date before use. Do not use the product if the date has passed.

  • Do Not Use if Package Integrity is Compromised

If the packaging is damaged or suspected to be non-aseptic, do not use the product.

Symbols and Explanations

Sl. No.SymbolTitle of the symbol
1 Date of manufacture
2 Use-by date
3 Sterilized using Ethylene Oxide
4 Do not reuse
5 Do not re-sterilize
6 Batch code
7 Keep away from sunlight
8 Keep dry
9 Caution
10 Do not use if the package is damaged
11Medical Device

SHIPPING POLICY

We strive to provide a seamless shipping experience for our customers. Here’s what you need to know:

Processing Time: Orders are generally processed and prepared for shipment within 1-2 business days after payment confirmation.

Shipping Methods: We offer various shipping options, including standard and expedited delivery services to meet your needs.

Shipping Rates: Shipping costs are calculated based on the destination and weight of the order. You can view the shipping fees during checkout before completing your purchase.

Delivery Time: Delivery times vary depending on your location and the selected shipping method. Estimated delivery times will be provided at checkout.

Tracking Information: After your order is shipped, you will receive a confirmation email with tracking details so you can monitor its progress.  

RETURN POLICY

We want you to be fully satisfied with your purchase. Here are the details of our return policy:

Full Credit: A full credit will be issued for any MAKVIN Surgical instrument returned within 90 days of the invoice date.

Non-Returnable Products: The following items are not eligible for return:

  – Any sterile product that has been opened

  – Any product returned outside of its original packaging

  – Any distributed product returned with damage to the box or label

  – Any custom etched instrument

  – Any custom made instrument

Return Process: To return any product(s) to Makvin Surgical, you must first obtain a Returned Goods Authorization (RGA) number. This number can be issued by contacting our customer service team at 1-800-xxx-xxxx. Please note that obtaining an RGA number does not guarantee final credit to your account. Makvin Surgical reserves the right to review and evaluate all returned items before issuing any credit.

For a return to be processed, all products must be sent back in their original condition. This includes returning the item(s) with all original packaging, boxes, bags, labels, and Instructions for Use (IFU).

If a product is deemed non-returnable, it will be sent back to the customer at our expense, along with a letter explaining the reason for its non-returnability.

Reviews

There are no reviews yet.

Be the first to review “STAB KNIFE 45 DEGREE”

Your email address will not be published. Required fields are marked *

Scroll to Top